Page view 8
9
20/02/09 - 300015144-001-C C 230 ECO
4.2 Changing the settings
4.2.1 Control panel DIEMATIC-m3
Keys accessible when the flap is closed Keys accessible when the flap is open
Z
See Control panel instructions
Adjustment keys
MODE Various operating modes can be selected by
successively pressing key MODE:
`
AUTOMATIQUE
` DAY 7/7: Forced operation at permanent Day temperature
` DAY (Until midnight): Forced operation at temporary Day
temperature
` NIGHT 7/7: Forced operation at permanent Night
temperature
` NIGHT (Until midnight): Forced operation at temporary
Night temperature
` DAYS ANTIFREEZ: Antifreeze mode for the number of
days set
` ANTIFREEZ 7/7: Permanent antifreeze mode
Restart key for a DHW calorifier load
`
AUTOMATIQUE
` DHW: Restarts DHW load until midnight
` DHW 7/7: DHW load is forced permanently
After a few seconds, the display disappears but the mode
is activated.
+
Display key for the various counters (number of burner
start-ups, number of burner operating hours, etc.)
2%
Set temperatures Day (Heating / DHW / Pool)
2$
Set temperatures Night (Heating / DHW)
*
Access key to the slave boilers (Panel K3) in a cascade
If using only one boiler, this key is inactive.
(
Setting the gradients for circuits A, B and C
)
Setting the parallel offsets DECAL.// DEP.A, DECAL.//
DEP.B or DECAL.// DEP.C for the heating curves on
circuits A, B or C.
If the Day setting for one of the circuits, A, B or C, is
above 30°C, you no longer have access parallel offset on
this circuit.
+/- Adjustment keys
Adjustment keys
%O
Enter (per 1/2 hour) the comfort temperature
period or tank load enabled (dark area).
$P
Enter (per 1/2 hour) the reduced temperature
period or tank load disabled (light area).
STANDARD
Simultaneously pressing the 2 keys,
%O
and
$P
, resets all of the time programmes.
S
Return key
J
Page scrolling
I
Line scrolling
*
Scroll of boilers connected
#
Manual "Summer" shutdown key. The heating is
switched off and DHW production is ensured.
K
Fitter settings access key
M
Sweep key