Page view 63
64
71.06199.02 - EN
OPERATING INSTRUCTIONS
10. TROUBLESHOOTING
N.B.: in case of a fault, the display backlighting ashes together with the error code.
To keep the boiler efcient and safe, have it checked by the authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily ammable cleaners (e.g.: petrol,
alcohol, and so on). Always switch off the appliance before cleaning it (see section 7 Switching off the boiler).
11. ROUTINE MAINTENANCE INSTRUCTIONS
Faults are shown on the display with an error code (e.g.: E 01):
CODE
DISPLAYED
FAULT CORRECTIVE ACTION
E01 Failed ignition shutdown
Press and hold down “R” for at least 2 seconds. If this fault persists, call the
Authorised Service Centre.
E02 Safety thermostat tripped
Press and hold down “R” for at least 2 seconds. If this fault persists, call the
Authorised Service Centre.
E03
Flue thermostat/ ue pressure
switch tripped
Call the Authorised Service Centre.
E04
Shutdown after 6 consecutive
ame losses
Press and hold down “R” for at least 2 seconds. If this fault persists, call the
Authorised Service Centre.
E05 Flow sensor failure Call the Authorised Service Centre.
E06 DHW sensor fault Call the Authorised Service Centre.
E10
Hydraulic pressure switch
block
Check that the pressure in the system is correct; See section 6. If this fault
persists, call the Authorised Service Centre.
E25/E26
Probable blocked pump safety
trip
Call the Authorised Service Centre.
E35 Parasite ame (ame error)
Press and hold down “R” for at least 2 seconds. If this fault persists, call the
Authorised Service Centre.
E96
Switching off due to reductions
in power supply
RESET is automatic. If this fault persists, call the Authorised Service Centre
To RESET the boiler, press and hold down “R” for at
least 2 seconds. If this fault persists, call the Authorised
Service Centre.
N.B.: 5 reset attempts can be performed after which
the boiler shuts down. To reset again, switch off the
boiler for a few seconds.